    Kelly KLS 7218-M Identification not working

    So, it turns out I’m a numpty, the controller needs full voltage to pin 7 not 12v (13.8v) as I had supplied. I read the 12v signal supplies from bike switches and assumed all pins on this plug would be 12v. Fany from Kelly Controls put sorted it for me and I must compliment him on the rapid...
  2. J

    Kelly KLS 7218-M Identification not working

    One other difference I have is the controller pin 7 is powered by 12v (13.8v) from dc to dc converter, not the 72v directly from the battery. The B+ is 72v from the battery. Could this cause the issue above? Markup of controller diagram below:
  3. J

    Kelly KLS 7218-M Identification not working

    I have a document from golden motor stating 5 pole pairs for the 3kW motor and 4 for the larger 5kW motor. I understand this is only used to calculate the speed and not used for the identity. I will try with 4 pole pairs (8) to see if that works. I would have expected some rotation of the motor...
  4. J

    Kelly KLS 7218-M Identification not working

    Thanks for the responses. In monitor mode during the identify operation the temperature reads 246. When not performing the identify operation this seems to read correctly with temperatures around 22degC which is about right for my garage. Motor is also cool to touch and has not had any...
  5. J

    Kelly KLS 7218-M Identification not working

    Hi All, I’m a long time stalker of endless sphere and the great info available here, but this is my first post. I quite enjoy the electric vehicle thing and I have built three e-bikes (really just plug and play), I have an electric skateboard which is also occasionally used to get me to and...