I won't say for all cases, but from what I was able to analyze, my CRC works without a multiplier. Most compensate with a multiplier for the presence of B0, B12 in their formula.
Is the CRC I suggested not working?
LCD>controller CRC = (xor B1,B2,B3,B4,B6,B7,B8,B9,B10,B11)
controller>LCD CRC = (xor B1,B2,B3,B4,B5,B7,B8,B9,B10,B11)
Check that PAS is not "0".
Try to activate "6KM / H power assistant push function"
Try turning on the controller without a display. (A jumper in the connector).
Check the pins in the display connector.
Measured Tektronix A622, current in green or battery (13s) wire. The voltage is about 50-52V.
I loaded the wheel with a disc brake, in time it is a couple of seconds and the controller turns off the motor (8fan bpm 10t). Pictures for the initially locked wheel and rotating with the subsequent...
Perhaps in the original, it can give out more than 70-80A, but it will surely get hot even from lower currents. C5, but I didn't watch it.
I don't understand the simulator. In my understanding, there are 3 phases in the motor .... if you count the rms, then for 3 phases with 80A amplitude...
lcd8 manual:
"L Parameter Setting
1. L1 parameters are applicable to the automatic under-voltage controller. The
default of the factory is 0.
1.1 When L1=0, the automatic under-voltage controller can automatically select
the under-voltage value according to the battery voltage.
1.2 When L1=1...
Hi
How to check supports stock controller sensor temperature of the motor?
Perhaps you have a stock controller circuit supporting a motor temperature sensor?