Search results

  1. O

    DIY Outboard

    no che un video
  2. O

    DIY Outboard

    For my 1967 wooden Boat which I fully reworked, I have designed and built an outboard engine. It is a 85165 fully waterproof BL Innerrunner, capable of 18Kw (according to the maker) As I can run only 4,4Kw becuase of local laws, it will be a long lasing motor I hope. I am running it on a 14S1P...
  3. O

    Active pre-charge/inrush control

    I am using this resitor; https://www.conrad.at/de/p/hochlast-widerstand-6-8-axial-bedrahtet-5-w-tru-components-tc-prw05wjw68jb00203-1-st-1583571.html no heatso far, but I did not put any load to the system, just switch on/off several times. About C1, this one does not have to be higher voltage...
  4. O

    Active pre-charge/inrush control

    Today I tried again with a switch. Now in fact it is working. Sorry for the confusion
  5. O

    Active pre-charge/inrush control

    Well, as mentioned the esc had full power before I could switch to the 10Ohm resistor
  6. O

    Active pre-charge/inrush control

    Battery voltage is 14S Liion so around 54V capacitance is 6x 560µF I can not measure the time. And I did not use a switch, but a wire to manually "do" the switch. So my switching time might be longer than 1 sec. In this time the controller already got full voltage, before I "switched" to ON...
  7. O

    Active pre-charge/inrush control

    Did anyone built this one? I am waiting for the parts.
  8. O

    Active pre-charge/inrush control

    I used this Mosfets Infineon Technologies IRFB7730PBF MOSFET 1 N-Kanal 375 W TO-220AB And yes I am sure I have built it correct. Did it 2 times. Same result, in the moment you open the switch from the "off" pos, the esc is switched on.
  9. O

    Active pre-charge/inrush control

    Well I have build it. And it does not work
  10. O

    Active pre-charge/inrush control

    what part is suitable for Q3? Q1 can be the same as Q4,5...?
  11. O

    Active pre-charge/inrush control

    This circuit does not work. As soon as you open the switch from the off position, the controller gets full voltage, Seems the 10Ohm is useless.
  12. O

    Active pre-charge/inrush control

    When you switch on, you connect + to - via 200k ??
  13. O

    Active pre-charge/inrush control

    I cant see this cap in your pcba, did you skip it?
  14. O

    Active pre-charge/inrush control

    nice, what current are you using it with cont.? And can this recuperate?
  15. O

    can someone identify this controller? I need a manual

    Thank you. Is this a reliable and good controller?
  16. O

    can someone identify this controller? I need a manual

    https://www.ebay.at/itm/404261320112?mkcid=16&mkevt=1&mkrid=5221-175123-2357-0&ssspo=3eazddijt8o&sssrc=4429486&ssuid=7fLuVLK7TVO&var=&widget_ver=artemis&media=MORE
  17. O

    Active pre-charge/inrush control

    correct, this one. Yeah it is large, but it goes into my boat, so no problem.
  18. O

    Active pre-charge/inrush control

    here is my rednek solution On pos1 it is a 10 Ohm resistor. On 2 it is direct.
  19. O

    Active pre-charge/inrush control

    is it possible to use the existing design with such a mosfet...
  20. O

    Active pre-charge/inrush control

    Hello Fechter, any news on your new design? I
  21. O

    Active pre-charge/inrush control

    I think this MRR can create quite some current peaks, which create some back emf?
  22. O

    Active pre-charge/inrush control

    Is there any progress in the antispark switch design? I build some after sheme No.3 and they worked fine, only they do not survive a motorrecognition run by VESC tool. Any ideas how to prevent this?
  23. O

    Active pre-charge/inrush control

    Thanks a lot.
  24. O

    Active pre-charge/inrush control

    Hello Fechter thanks for the reply. Does this circuit consume any current when connected to the battery? I am thinking of placing it inside my battery box. I used 6 of the 100v FET‘s you suggested. Placed on a 6mm Aluminium Heat sink around 65x50mm. What do you think it can handle as cont...
  25. O

    Active pre-charge/inrush control

    I am building this switch right now. Can I use this capacitor for it? It is 1µF Thanks for the help Toto
Back
Top