  1. M

    Flipsky 75100 sensor detection fail help

    Change your APP CFG postive ramp time to 0.1s or even less. And adjust your throttle curve. Under Hall sensors, Sensorless erpm - 4000 or above Hall interpolation Erpm - 300 All these should already provide good improvement.
  2. M

    VESC Tuning Advice, Poor Acceleration compared to other controllers

    Go to APP CFG , ADC section and Check your positive ramp time and decrease it to 0.1 or even less. And adjust your throttle curve to 15%-20% exponential. You should see acceleration improvement.